Please use this identifier to cite or link to this item: https://essuir.sumdu.edu.ua/handle/123456789/87544
Or use following links to share this resource in social networks: Recommend this item
Title Sedimentation Tanks for Treating Rainwater: CFD Simulations and PIV Experiments
Authors Czernek K., K.
Ochowiak, M.
Janecki, D.
Zawilski, T.
Dudek, L.
Witczak, S.
Krupińska A., A.
Matuszak, M.
Włodarczak, S.
Hyrycz, M.
Pavlenko, Ivan Volodymyrovych  
ORCID http://orcid.org/0000-0002-6136-1040
Keywords CFD
PIV
rainwater treatment
sedimentation tank
swirl motion
Type Article
Date of Issue 2021
URI https://essuir.sumdu.edu.ua/handle/123456789/87544
Publisher MDPI
License Creative Commons Attribution 4.0 International License
Citation Czernek, K.; Ochowiak, M.; Janecki, D.; Zawilski, T.; Dudek, L.; Witczak, S.; Krupińska, A.; Matuszak, M.; Włodarczak, S.; Hyrycz, M.; Pavlenko, I. Sedimentation Tanks for Treating Rainwater: CFD Simulations and PIV Experiments. Energies 2021, 14, 7852. https://doi.org/10.3390/en14237852
Abstract The removal of solids is the most important step when treating rainwater. The article evaluates two designs of sedimentation tanks that can be used for the continuous separation of fine particles from water: OS—standard sedimentation tanks, and OW—swirl sedimentation tanks. The tanks were studied by conducting computational fluid dynamics (CFD) modeling and particle image velocimetry (PIV) experiments. The settling process in sedimentation tank was carried out at varying operating flow rates. A tank with a modified structure was used for the tests, where water was supplied by a nozzle placed at an angle. This solution made it possible to obtain a rotational flow that transported the suspended particles towards its wall, where downward axial velocity resulted in the settling of particles. Based on the research, it was observed that the flow patterns showed inward flow at the bottom of the tank and an upward flow and the lifting of the settled particles near the hatch at the bottom. The presented experimental measurements provided detailed insight into flow patterns, and valuable calibration and verification data for further CFD modeling. Traditional PIV techniques are useful in the case of standard design, whereas CFD is invaluable for supporting this work and for investigating the design of novel sedimentation tanks.
Appears in Collections: Наукові видання (ТеСЕТ)

Views

China China
859348
Finland Finland
286
Germany Germany
46460
Greece Greece
558
Ireland Ireland
27592
Lithuania Lithuania
1
Singapore Singapore
1
Ukraine Ukraine
429675
United Kingdom United Kingdom
92917
United States United States
1718696
Unknown Country Unknown Country
1
Vietnam Vietnam
560

Downloads

China China
1
Germany Germany
92924
India India
46459
Indonesia Indonesia
1
Iran Iran
1
Ireland Ireland
1
Italy Italy
1
Lithuania Lithuania
1
Morocco Morocco
46457
Peru Peru
1
Romania Romania
1
South Africa South Africa
1
Spain Spain
1
Ukraine Ukraine
859348
United Kingdom United Kingdom
1
United States United States
3176096
Vietnam Vietnam
1

Files

File Size Format Downloads
Czernek_et_al_Sedimentation_Tanks_2021.pdf 30,01 MB Adobe PDF 4221296

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.